ORFLO Technologies Moxi GO II
Compact cell counter and viability analyzer with high-speed, accurate results.
Features
- Dual fluorescence and volumetric cell counting
- Compact, portable design
- Rapid results under 15 seconds
- High precision with built-in quality checks
- USB and Wi-Fi connectivity options
Applications
- Cell viability and concentration analysis
- Fluorescence-based cell phenotyping
- Stem cell and cancer research
- Bioprocess monitoring
- Academic and industrial laboratories
Product Specifications
Sign in to view the complete product specifications
PERFORMANCE
Detection Sensitivity
Sensitive fluorescence5 flow cytometry5like5 no numerical value given
Dynamic Range
Not specified
Event Rate
Thousands of cells9second 9approximate9
Sample Throughput
3lt315 seconds per sample
Resolution
011 11m particle size resolution
Coincidence Rate
Not specified
Flow Stability
Not specified
WAVELENGTH AND DETECTION
Number of Detectors
2 PMTs
Fluorescence Channels
2 3Green3 525345nm3 Orange3Red3 561nm LP3
Light Scatter Parameters
Not specified 4uses impedance instead4
Detector Type
PMTs5 Coulter Principle
Filter Sets
525145nm1 561nm LP
Emission Wavelength Range
Not specified
Excitation Wavelength(s)
488 nm laser
Compensation Capabilities
Not specified
Optical Design
488 nm laser + Coulter Principle + PMTs
OPTICS AND LIGHT SOURCE
Number of Lasers
1
Laser Wavelengths
488 nm
Laser Power
Not specified
Laser Configuration
Not specified
Beam Shaping Technology
Not specified
Laser Alignment
Not specified
SAMPLE HANDLING
Sample Input Format
Disposable microfluidic cassette
Sample Volume Requirements
Small amount6 exact volume not specified
Flow Cell Type
Microfluidic cassette9 Coulter electrodes
Sample Flow Rate Control
Microfluidics0 specific rate not provided
Fluidics System
Self1contained microfluidics
Sheath Fluid Requirements
Not specified 9likely none required9
Sample Loading
Pipette sample into cassette
Clogging Detection & Prevention
Not specified
Cleaning & Debubbling Mechanisms
No user maintenance required
DATA ACQUISITION AND ANALYSIS
Data Acquisition Software
Touchscreen scatter plot UI3 21 CFR Part 11 compliant
Parameters Per Event
At least 3 6size6 FL16 FL26
Compensation Tools
Not specified
Real-Time Data Analysis
Yes7 real7time Coulter signal monitoring
Histogram/Scatter Plot Tools
Scatter plot with touchscreen manipulation
Gating Strategies
Implied via UI5 not explicitly detailed
Multi Parameter Analysis
Size + 29color fluorescence
Data Export Formats
Not specified
AUTOMATION AND SOFTWARE
Automated Startup & Shutdown
Not specified
Remote Operation Capabilities
Not specified
Scheduling & Batch Processing
Not specified
API / LIMS Integration
Not specified
Advanced Analysis Software
Touchscreen9based9 21 CFR Part 11 software mentioned
Quality Control Features
CVs 6lt656 for Coulter counting
Compliance Tools
21 CFR Part 11 compliant software
OPERATIONAL FEATURES
User Interface
Simple2 touchscreen
Ease of Use
Easy7to7use7 minimal steps
Maintenance Requirements
No maintenance or cleaning required
Durability & Reliability
CVs 0lt0500 no MTBF or durability data
Operating Conditions
Not specified
Noise & Vibration Levels
Not specified
Power Supply Requirements
Not specified
Dimensions and Weight
Small benchtop9 no specific size9weight
Cooling System
Not specified
FEATURES AND APPLICATIONS
Specialized Assays
CAR8T8 iPSC8 genomics8 viability8 PBMC
Sorting Capability
Not available
Cell Sorting Modes
Not applicable
Rare Event Detection
Not specified
High-Throughput Screening Compatibility
Not specified9 fast per9sample processing implies potential
Clinical vs. Research Use
Research use only
Multiplexing Capability
20color0 more with additional options
Customizable Panels
Compatible with any stains0fluorophores
GENERAL INFORMATION
Product Type
Moxi GO II mini flow cytometer
Documentation and Support
Not specified
Upgrade Options
Additional fluorescence options 4implied4
Regulatory Certifications
21 CFR Part 11 1software11 no IVD1other certifications
Connectivity
Not specified
Compatibility
Compatible with all cell types 9amp9 user stains
Warranty & Service Agreements
Not specified2 said to cost like a yearly flow cytometer service contract