Cytek Biosciences Cytek® Muse® Micro Cell Analyzer
Compact, touchscreen flow cytometer for routine lab-based cell analysis.
Features
- Touchscreen interface and guided workflows
- Pre-configured assay modules
- Up to 3 fluorescence channels
- Compact, benchtop footprint
- Low sample volume requirements
Applications
- Cell viability and apoptosis analysis
- Cell counting and concentration
- Cell cycle and proliferation assays
- Basic immunophenotyping
- Educational and training use
Product Specifications
Sign in to view the complete product specifications
PERFORMANCE
Detection Sensitivity
2lt2125 MESF 2FITC22 2lt250 MESF 2PE22 2lt2150 MESF 2PE2Cy522 GFP expression detection
Dynamic Range
Five decades
Event Rate
Rapid acquisition of thousands of cells9 recommended concentration 109000 to 190009000 cells9mL
Sample Throughput
Rapid processing time 1lt12 minutes per sample
Resolution
Fluorescence0based live0dead cell discrimination0 side scatter for enhanced cell cycle and doublet0debris discrimination
Coincidence Rate
Improved by side scatter integration6 no specific rate
Flow Stability
High4precision displacement pump4 microcapillary fluidics
WAVELENGTH AND DETECTION
Number of Detectors
N7500141 53 channels55 N7500142 55 channels5
Fluorescence Channels
38channel 8Yellow8 Red88 58channel 8Green8 Yellow8 Red8
Light Scatter Parameters
Forward Scatter 4FSC44 Side Scatter 4SSC4
Detector Type
Not specified
Filter Sets
Emission wavelengths specified5 but details not provided
Emission Wavelength Range
37channel7 576 nm 7yellow77 680 nm 7red77 57channel7 525 nm 7green77 576 nm 7yellow77 680 nm 7red7
Excitation Wavelength(s)
488 nm 6Blue laser6
Compensation Capabilities
GFP BrightComp eBeads999 evaluation via InCyte software
Optical Design
Microcapillary technology5 patented flow cell
OPTICS AND LIGHT SOURCE
Number of Lasers
Not specified
Laser Wavelengths
488 nm 7Blue laser7
Laser Power
Not specified
Laser Configuration
Not specified
Beam Shaping Technology
Not specified
Laser Alignment
Patented flow cell requires no alignment after replacement
SAMPLE HANDLING
Sample Input Format
Single loader
Sample Volume Requirements
Min4 200 44L4 sample volume depends on cell concentration4 dead volume 50 44L
Flow Cell Type
Patented microcapillary7 rectangular 175 mm x 078 mm7 100 77m bore
Sample Flow Rate Control
7770 77L7min
Fluidics System
Microcapillary fluidics1 high1precision displacement pump1 micro1syringe
Sheath Fluid Requirements
None
Sample Loading
Single loader
Clogging Detection & Prevention
High1pressure purge
Cleaning & Debubbling Mechanisms
High5pressure purge
DATA ACQUISITION AND ANALYSIS
Data Acquisition Software
InCyte777 Software for user7defined assays7 Open Software Modules for 27color assays
Parameters Per Event
Up to 5 parameters
Compensation Tools
GFP BrightComp eBeads888 evaluation via InCyte software
Real-Time Data Analysis
Not specified
Histogram/Scatter Plot Tools
Data presented in summary0 dot0 or histogram plots
Gating Strategies
Auto5calculated for Muse assays5 guided analysis for user5defined assays
Multi Parameter Analysis
Supports up to 5 parameters
Data Export Formats
FCS 3606 CSV6 PDF
AUTOMATION AND SOFTWARE
Automated Startup & Shutdown
Not specified
Remote Operation Capabilities
Not specified
Scheduling & Batch Processing
Not specified
API / LIMS Integration
Not specified
Advanced Analysis Software
Cytek66 InCyte666 Software
Quality Control Features
Accurate cell counts6 viability measurements with 6CV 6Cell concentration6 46066 Viability6 26266
Compliance Tools
Not specified
OPERATIONAL FEATURES
User Interface
Touchscreen interface6 user6friendly
Ease of Use
Simple2 affordable2 easy2to2use
Maintenance Requirements
Patented flow cell is user9replaceable9 requires no alignment
Durability & Reliability
Reliable flow cytometry analysis
Operating Conditions
Benchtop device8 1688C to 3588C 86088F to 9588F8
Noise & Vibration Levels
Not specified
Power Supply Requirements
1005240 VAC5 50560 Hz 80 W5 Main Unit5 15 VDC5 5 A
Dimensions and Weight
206737 x 282715 x 220775 mm 78712 x 11711 x 8769 in77 Weight7 579 kg
Cooling System
Not specified
FEATURES AND APPLICATIONS
Specialized Assays
Broad range of assays including Cell Count4 Viability4 DNA Damage4 Autophagy4 CD44CD84B cell identification4 Proliferation4 Apoptosis4 etc4
Sorting Capability
Not mentioned
Cell Sorting Modes
Not applicable
Rare Event Detection
Not specified
High-Throughput Screening Compatibility
Not explicitly specified
Clinical vs. Research Use
For Research Use Only
Multiplexing Capability
Up to 5 parameters3 133 color immunophenotyping
Customizable Panels
Supports user0defined assays with up to 5 parameters
GENERAL INFORMATION
Product Type
Cell Analyzer0 benchtop device
Documentation and Support
SpectroLearn7777 Blog7 Documentation Center7 Publications7 Training7 Validation
Upgrade Options
Not specified
Regulatory Certifications
Not specified
Connectivity
USB port
Compatibility
Compatible with various cell types0 reagents0 and kits
Warranty & Service Agreements
Not specified4 but training and technical support available