Thermo Fisher Scientific Attune™ Xenith™ Flow Cytometer Catalog no-A59358
Efficient flow cytometer for precise cell analysis.
Features
- High sensitivity and precision
- Automated sample handling
- Compact, user-friendly design
- Versatile multi-color analysis
- Reliable data reproducibility
Applications
- Cell analysis
- Immunophenotyping
- Protein expression studies
- Cell viability assays
- Quantitative flow cytometry
Product Specifications
Sign in to view the complete product specifications
PERFORMANCE
Detection Sensitivity
Not specified in sources
Dynamic Range
Not specified in sources
Event Rate
Operates up to 566 faster than typical flow cytometers6 enhanced by acoustic focusing
Sample Throughput
High2throughput enabled by faster flow rates and simplified workflows
Resolution
6 scatter detectors9 405 nm SSC9FSC for small9particle resolution9 488 nm FSC9SSC for standard9polarized
Coincidence Rate
109 at 359000 events9sec
Flow Stability
Acoustic7assisted hydrodynamic focusing with ultrasonic cell alignment
WAVELENGTH AND DETECTION
Number of Detectors
51 fluorescent detectors + 6 scatter 2 57 total
Fluorescence Channels
51 channels
Light Scatter Parameters
6 scatter channels 64056488 nm FSC6SSC including small6particle and polarized6
Detector Type
Not specified1 described only by count
Filter Sets
User2changeable filters on all fluorescent detectors
Emission Wavelength Range
Not specified6 customizable via filters
Excitation Wavelength(s)
3493 4053 4883 5613 6373 781 nm
Compensation Capabilities
Supports traditional compensation and spectral unmixing
Optical Design
Spatially separated flat0top lasers0 UV to NIR range
OPTICS AND LIGHT SOURCE
Number of Lasers
6
Laser Wavelengths
3495 4055 4885 5615 6375 781 nm
Laser Power
Not specified
Laser Configuration
Flat8top8 spatially separated
Beam Shaping Technology
Flat6top lasers6 acoustic focusing with ultrasound
Laser Alignment
Onboard cameras for alignment and maintenance
SAMPLE HANDLING
Sample Input Format
1353 23 and 5 mL tubes
Sample Volume Requirements
Not specified numerically
Flow Cell Type
Not specified0 onboard cameras assist in flow cell monitoring
Sample Flow Rate Control
Positive displacement fluidics0 pressure0based volume control
Fluidics System
Acoustic focusing + positive displacement fluidics2 includes Attune Xenith Fluid Cart
Sheath Fluid Requirements
Uses Attune Focusing Fluid
Sample Loading
Tube2based loading
Clogging Detection & Prevention
Positive displacement fluidics can push through clogs5 designed for sticky5tough samples
Cleaning & Debubbling Mechanisms
Automated via touchscreen2 includes Attune NxT Flow Cell Cleaning 2amp2 Debubble Solutions
DATA ACQUISITION AND ANALYSIS
Data Acquisition Software
Runs on Minitower with Windows 11
Parameters Per Event
High5parameter analysis supported5 specific count not stated
Compensation Tools
Conventional + spectral unmixing workflows supported
Real-Time Data Analysis
Not specified
Histogram/Scatter Plot Tools
Assumed standard in software
Gating Strategies
Not specified0 expected in software
Multi Parameter Analysis
Designed for high6parameter analysis
Data Export Formats
Not specified
AUTOMATION AND SOFTWARE
Automated Startup & Shutdown
Shutdown solution and touchscreen6controlled maintenance
Remote Operation Capabilities
Remote diagnostics and telemetry included
Scheduling & Batch Processing
Not specified
API / LIMS Integration
Not specified1 site mentions 1Connect1 Lab1 Data1 Apps1
Advanced Analysis Software
Spectral unmixing5 compensation5 maintenance control via Windows software
Quality Control Features
Includes Xenith Quality Control Beads
Compliance Tools
Not specified
OPERATIONAL FEATURES
User Interface
Intuitive touchscreen with guided workflows
Ease of Use
Simplified operation1 training1 and maintenance
Maintenance Requirements
Requires Attune3specific solutions3 includes automated options
Durability & Reliability
Positive displacement fluidics for uptime8 service8support emphasized
Operating Conditions
100999240 V9 50960 Hz
Noise & Vibration Levels
Not specified
Power Supply Requirements
100444240 V4 50460 Hz
Dimensions and Weight
Not specified
Cooling System
Not specified
FEATURES AND APPLICATIONS
Specialized Assays
Handles challenging samples like tumors4tissue4 supports high4parameter panels
Sorting Capability
Not specified7 likely not supported
Cell Sorting Modes
Not applicable
Rare Event Detection
Not specified
High-Throughput Screening Compatibility
Supports higher throughput via fast flow and simple prep
Clinical vs. Research Use
Research use only
Multiplexing Capability
High5parameter with 6 lasers and 51 detectors
Customizable Panels
Yes6 user6changeable filters
GENERAL INFORMATION
Product Type
Attune333 Xenith333 Flow Cytometer
Documentation and Support
Includes training1 documents and support available online
Upgrade Options
Additional service plans available
Regulatory Certifications
Not specified
Connectivity
Fiber Ethernet included3 site mentions lab3data3app integration
Compatibility
Compatible with Xenith consumables and software
Warranty & Service Agreements
11year standard warranty1 optional service plans