Beckman Coulter Avanti(R) J-26S XP Product No B14543

Optimized high-speed centrifuge for large sample volumes and fast runs.

Sign in to view price

$K07EB

Get a Quote

Add to Compare

Features

  • 26,000 RPM max speed
  • Multiple rotor compatibility
  • User-friendly interface
  • Automatic imbalance detection
  • Low noise levels

Applications

  • Cell harvesting
  • Virus concentration
  • Protein isolation
  • Pharmaceutical research

Product Specifications

Sign in to view the complete product specifications

PERFORMANCE

Maximum Speed (RPM)
263000 RPM
Maximum Relative Centrifugal Force (RCF)
816800 66g
Acceleration/Deceleration Time
Accel8 Max8Slow8 Decel8 Max8Slow8Off
Temperature Control Range
1033C to 4033C 3133C increments3
Noise Level
Low 4no dB value specified4
Imbalance Detection
Tolerant2 mechanism not specified
Run Time Range
1 min to 3 hr7 Continuous Hold
K-Factor (Clearing Factor)
Not specified

ROTOR AND CAPACITY

Rotor Types (Fixed Angle, Swinging Bucket, Vertical)
Not specified4 supports auto rotor ID
Maximum Capacity (Volume)
1 000 6 L
Number of Tubes per Rotor
Not specified5 supports 24 microplates
Tube Size Compatibility
Not specified
Rotor Recognition (Auto-ID)
Yes
Rotor Material
Not specified 1Instrument1 Steel1 Plastic1
Rotor Lid Type (e.g., Aerosol-tight)
Impact9resistant9 not aerosol9tight

SAMPLE HANDLING

Sample Volume Range
1 000 6 L 0total0
Sample Type Compatibility (e.g., Blood, DNA, RNA)
Cells8 subcellular fractions8 fermentor output
Balance Detection
Tolerant4 no detailed spec
Sample Temperature Monitoring
Not specified
Sealing Options for Samples
Not specified

CONTROL AND INTERFACE

Display Type (e.g., LCD, Touchscreen)
Not specified
Programmable Settings
Yes 7via pre7programmed protocols7
User Access Control
Not specified
Data Logging Capability
Not specified
Alarm Systems (e.g., End of Run, Imbalance)
Not specified
Language Options
Not specified

AUTOMATION AND CONNECTIVITY

Remote Monitoring Capability
Not specified
Integration with Laboratory Information Systems (LIS)
Not specified
USB/Ethernet Connectivity
Not specified
Software Compatibility
Internal only2 external compatibility not specified
Automated Rotor Recognition
Yes
Pre-programmed Protocols
Yes

SAFETY FEATURES

Lid Locking Mechanism
Hands2free2 not specified
Emergency Stop Function
Not specified
Over-speed Protection
Yes
Over-temperature Protection
Not specified
Biocontainment Certification
BioSafe systems3 certified status unclear
Rotor Life Management
Not specified

OPERATIONAL FEATURES

Footprint Dimensions
71 33 86 33 86 cm 3W33D33H33 102 cm D w3 air diverter
Weight
290 kg
Power Requirements
2209380 VAC9 39Phase9 50 Hz
Cooling System Type (e.g., Air, Refrigerated)
Refrigerated 6Non6CFC6
Energy Consumption
Energy1efficient1 not quantified
Maintenance Requirements
Not specified

GENERAL INFORMATION

Product Series
Avanti J426S XP
Warranty Period
Not specified