You have chosen to compare
Sign in to view price
$L5U6ZSPERFORMANCE
Magnification Range
Numerical Aperture (NA)
Resolution
Field of View (FOV)
Depth of Field
Contrast Methods
Optical System Type
AUTOMATION AND SOFTWARE
Motorized Components
Automated Imaging Sequences
Software for Image Analysis
Remote Operation Capability
Data Export Formats
Integration with Laboratory Information Systems (LIS)
OPERATIONAL FEATURES
Ergonomic Design
Modular Expandability
Maintenance Requirements
Power Supply Specifications
GENERAL INFORMATION
Product Series
Technical Support Availability

Thermo Fisher Scientific Axia ChemiSEM
Sign in to view price
$EOGK1VPERFORMANCE
Magnification Range
5× to 1,000,000×
Numerical Aperture (NA)
Not specified
Resolution
3.0–10.0 nm (varies by kV and mode)
Field of View (FOV)
Large FOV, e.g., 106 µm at 1200×
Depth of Field
Not specified
Contrast Methods
SE, BSE, ChemiSEM, BD mode
Optical System Type
Thermal emission SEM, tetrode source, 45° objective lens
AUTOMATION AND SOFTWARE
Motorized Components
Motorized stage, BSE detector, Z-axis
Automated Imaging Sequences
AutoScript 4, Maps Software, montage mode
Software for Image Analysis
TopoMaps, ChemiView, ChemiPhase, Perception
Remote Operation Capability
Optional remote software, RAPID™ support
Data Export Formats
TIFF, JPEG, BMP
Integration with Laboratory Information Systems (LIS)
Not specified
OPERATIONAL FEATURES
Ergonomic Design
Easy loading, customizable GUI, user guidance
Modular Expandability
5 ports, accessory & detector options
Maintenance Requirements
Easy source exchange, auto alignments, global support
Power Supply Specifications
100–240 VAC, 50/60 Hz, <2.0 kVA
GENERAL INFORMATION
Product Series
Thermo Scientific Axia ChemiSEM
Technical Support Availability
Global support, video/manual guidance, 1-year warranty

Leica Microsystems Mica Microhub
Sign in to view price
$OFI18XPERFORMANCE
Magnification Range
Included: 1.6x, 10x; Optional: 20x, 40x W/Oil, 63x W/Oil; fast widefield overviews + zoom
Numerical Aperture (NA)
Examples: 0.32 (10x), 0.70 (20x DRY), 0.75 (20x CS2), 1.2 (63x W motCORR CS2), 1.20 (63x water)
Resolution
Highest 3D resolution via point scanning confocal; LIGHTNING enhancement; no numeric values
Field of View (FOV)
Supports widefield overviews with zoom; numeric values not specified
Depth of Field
THUNDER clearing (ICC, SVCC, LVCC); point scanning confocal for thick 3D samples
Contrast Methods
Integrated Modulation Contrast (IMC), brightfield (RGB/grayscale), unified transmitted & fluorescence
Optical System Type
Combined widefield & point scanning confocal with transmitted & fluorescence modalities
AUTOMATION AND SOFTWARE
Motorized Components
Fully motorized and intelligently automated opto-digital components
Automated Imaging Sequences
Automated Z-stacks, time-lapse, sample finding, stitching, Mark & Find
Software for Image Analysis
"Learn & Results" pixel classifier (Aivia-powered), results traceable, compatible with Aivia
Remote Operation Capability
Not specified
Data Export Formats
Models/results exportable; formats not specified
Integration with Laboratory Information Systems (LIS)
Not specified
OPERATIONAL FEATURES
Ergonomic Design
Designed for bright lab use; fits in corner; no dark room needed
Modular Expandability
Optional Hypoxia, LIGHTNING Expert upgrades; 4 standard configs
Maintenance Requirements
Not specified; service & repair options available
Power Supply Specifications
Not specified
GENERAL INFORMATION
Product Series
Mica — world’s first Microhub
Technical Support Availability
Leica Application Support and Service & Repair; local contacts available