You have chosen to compare

Sign in to view price

$9YVI

PERFORMANCE

Magnification Range
Numerical Aperture (NA)
Resolution
Field of View (FOV)
Depth of Field
Contrast Methods
Optical System Type

AUTOMATION AND SOFTWARE

Motorized Components
Automated Imaging Sequences
Software for Image Analysis
Remote Operation Capability
Data Export Formats
Integration with Laboratory Information Systems (LIS)

OPERATIONAL FEATURES

Ergonomic Design
Modular Expandability
Maintenance Requirements
Power Supply Specifications

GENERAL INFORMATION

Product Series
Technical Support Availability
Labomed LB-573

Labomed LB-573

Sign in to view price

$U4HR

PERFORMANCE

Magnification Range

Objectives: 4×, 10× (reflected/transmitted); 20×, 40×, 60× (transmitted). Eyepieces: WF10×/20.

Numerical Aperture (NA)

Condenser NA 0.9 (Abbe). Objectives NA not specified.

Resolution

Stage graduated 2μm; vernier min resolution 6’; fine focus division 0.002mm. Optical res. not specified.

Field of View (FOV)

Eyepieces WF10×/20 (FN 20). Overall FOV not specified.

Depth of Field

Not specified.

Contrast Methods

Single polarization, orthogonal polarization, conoscopic observation; rotatable polarizer/analyzer; Bertrand lens.

Optical System Type

Excellent Infinite Optical System (Infinity Color Corrected).

AUTOMATION AND SOFTWARE

Motorized Components

Not specified.

Automated Imaging Sequences

Not specified.

Software for Image Analysis

Compatible with digital camera analysis; specific software not named.

Remote Operation Capability

Not specified.

Data Export Formats

Not specified.

Integration with Laboratory Information Systems (LIS)

Not specified.

OPERATIONAL FEATURES

Ergonomic Design

Seidentopf Trinocular Head inclined 30° for comfort; ergonomic not explicitly stated.

Modular Expandability

Optional accessories (Gypsum, Mica, Quartz slides; Mechanical stage; Optical compensators).

Maintenance Requirements

Not specified.

Power Supply Specifications

Illumination lamps: 12V/50W (Epi), 12V/30W (Transmitted); overall power specs not provided.

GENERAL INFORMATION

Product Series

LB-573 Polarizing Photo Microscope Trinocular Transmission & Reflection System; LB-572 model also mentioned.

Technical Support Availability

Labomed, Inc. contact info provided; specific support details not described.

Thermo Fisher Scientific Axia ChemiSEM

Thermo Fisher Scientific Axia ChemiSEM

Sign in to view price

$3ECUQB

PERFORMANCE

Magnification Range

5× to 1,000,000×

Numerical Aperture (NA)

Not specified

Resolution

3.0–10.0 nm (varies by kV and mode)

Field of View (FOV)

Large FOV, e.g., 106 µm at 1200×

Depth of Field

Not specified

Contrast Methods

SE, BSE, ChemiSEM, BD mode

Optical System Type

Thermal emission SEM, tetrode source, 45° objective lens

AUTOMATION AND SOFTWARE

Motorized Components

Motorized stage, BSE detector, Z-axis

Automated Imaging Sequences

AutoScript 4, Maps Software, montage mode

Software for Image Analysis

TopoMaps, ChemiView, ChemiPhase, Perception

Remote Operation Capability

Optional remote software, RAPID™ support

Data Export Formats

TIFF, JPEG, BMP

Integration with Laboratory Information Systems (LIS)

Not specified

OPERATIONAL FEATURES

Ergonomic Design

Easy loading, customizable GUI, user guidance

Modular Expandability

5 ports, accessory & detector options

Maintenance Requirements

Easy source exchange, auto alignments, global support

Power Supply Specifications

100–240 VAC, 50/60 Hz, <2.0 kVA

GENERAL INFORMATION

Product Series

Thermo Scientific Axia ChemiSEM

Technical Support Availability

Global support, video/manual guidance, 1-year warranty

Leica Microsystems Mica Microhub

Leica Microsystems Mica Microhub

Sign in to view price

$3Z2W1Q

PERFORMANCE

Magnification Range

Included: 1.6x, 10x; Optional: 20x, 40x W/Oil, 63x W/Oil; fast widefield overviews + zoom

Numerical Aperture (NA)

Examples: 0.32 (10x), 0.70 (20x DRY), 0.75 (20x CS2), 1.2 (63x W motCORR CS2), 1.20 (63x water)

Resolution

Highest 3D resolution via point scanning confocal; LIGHTNING enhancement; no numeric values

Field of View (FOV)

Supports widefield overviews with zoom; numeric values not specified

Depth of Field

THUNDER clearing (ICC, SVCC, LVCC); point scanning confocal for thick 3D samples

Contrast Methods

Integrated Modulation Contrast (IMC), brightfield (RGB/grayscale), unified transmitted & fluorescence

Optical System Type

Combined widefield & point scanning confocal with transmitted & fluorescence modalities

AUTOMATION AND SOFTWARE

Motorized Components

Fully motorized and intelligently automated opto-digital components

Automated Imaging Sequences

Automated Z-stacks, time-lapse, sample finding, stitching, Mark & Find

Software for Image Analysis

"Learn & Results" pixel classifier (Aivia-powered), results traceable, compatible with Aivia

Remote Operation Capability

Not specified

Data Export Formats

Models/results exportable; formats not specified

Integration with Laboratory Information Systems (LIS)

Not specified

OPERATIONAL FEATURES

Ergonomic Design

Designed for bright lab use; fits in corner; no dark room needed

Modular Expandability

Optional Hypoxia, LIGHTNING Expert upgrades; 4 standard configs

Maintenance Requirements

Not specified; service & repair options available

Power Supply Specifications

Not specified

GENERAL INFORMATION

Product Series

Mica — world’s first Microhub

Technical Support Availability

Leica Application Support and Service & Repair; local contacts available