PERFORMANCE

Mass Accuracy
Resolution
Sensitivity
Speed
Dynamic Range

MASS RANGE AND ANALYTE DETECTION

Mass Range
Detection Limit
Detector

IONIZATION, SOURCE AND INTERFACE

Ionization Method
Ion Source
Interface
Gas Flow and Requirements

MASS ANALYZER

Mass Analyzer
Quadrupole

CHROMATOGRAPHY AND SAMPLE HANDLING

Chromatography
Sample Handling
Injection System

DATA ACQUISITION AND ANALYSIS

Data Acquisition
Data Analysis

AUTOMATION AND SOFTWARE

Automation
Software

OPERATIONAL FEATURES

Ease of Use
Maintenance and Durability
Operating Conditions
Power and Cooling
Dimensions and Footprint

GENERAL INFORMATION

Brand and Model
Documentation and Support
Compatibility and Connectivity
Configuration and Options
Licensing and Certification
Cost and Operational Expenses
PerkinElmer NexION 1100 ICP Mass Spectrometer

PerkinElmer NexION 1100 ICP Mass Spectrometer

Sign in to view price

$YX86P

PERFORMANCE

Mass Accuracy

Less than 0.05 amu over 8 hours of continuous operation for 7Li, 24Mg, 115In, and 238U.

Resolution

Full-sized Transmission Analyzer Quadrupole provides custom resolution < 0.3 amu², typical operating resolution of < 0.7 amu.

Sensitivity

7Li > 20 Mcps/(mg/L)
115In > 100 Mcps/(mg/L)
238U > 80 Mcps/(mg/L)

Speed

The NexION 1100, with HTS flow injection, reduces sample processing time to 55s for 56 elements while minimizing carryover.

Dynamic Range

10¹⁰ with the option to increase it to 10¹⁴ using the Extended Dynamic Range (EDR) capability.

MASS RANGE AND ANALYTE DETECTION

Mass Range

1 - 285 amu

Detection Limit

9Be ≤ 0.4 ng/L
115In ≤ 0.1 ng/L
209Bi ≤ 0.1 ng/L

Detector

Dual-stage discrete dynode electron multiplier

IONIZATION, SOURCE AND INTERFACE

Ionization Method

Inductively Coupled Plasma (ICP)

Ion Source

Plasma

Interface

Triple Cone Interface (TCI)

Gas Flow and Requirements


  • Argon Gas Purity: ≥ 99.996%

  • Flow Rate: 12–20 L/min (typical: 15–20 L/min)

  • Pressure: 586–690 kPa (85–100 psig)

  • Cell Gas Purity: Refer to table below

MASS ANALYZER

Mass Analyzer

Quadrupole

Quadrupole

Triple-quad design consisting of:
Quadrupole Ion Deflector (Q0)
Quadrupole Universal Cell (Q1)
Transmission Analyzer Quadrupole (Q2)

CHROMATOGRAPHY AND SAMPLE HANDLING

Chromatography

Not applicable. The NexION 1100 ICP-MS is not designed for chromatography.

Sample Handling


  • All Matrix Solution (AMS) system enables up to 200x online dilution and handles samples with up to 35% total dissolved solids.

  • High Throughput System (HTS) ensures fast sample processing with NexION 1100.

Injection System

The NexION 1100 ICP-MS is compatible with a variety of autosamplers.

DATA ACQUISITION AND ANALYSIS

Data Acquisition

Discrete Dynode Detector allows for rapid data acquisition rates, capturing both analog and pulse signals simultaneously.

Data Analysis


  • Quantitative analysis: External calibration, matrix-matched calibrations, standard additions, isotope ratios, isotope dilutions.

  • Semi-quantitative analysis.

  • FastQuant™ Data Viewer for data review, processing, and export.

AUTOMATION AND SOFTWARE

Automation

Automated system startup, shutdown, optimization and instrument tuning (including torch alignment) are available through the Syngistix software.

Software

Syngistix™ for ICP-MS Software v.4.0 or higher

OPERATIONAL FEATURES

Ease of Use

LCD Touchscreen for critical day-to-day tasks including hardware control, results review, instrument parameter diagnostics, analytics, access to embedded training videos and more.
External status LED lighting for easy visibility of the state of analysis.
Syngistix for ICP-MS Software features user-friendly interface and intuitive workflows.

Maintenance and Durability


  • LumiCoil™ technology requires no maintenance, replacement, or cooling; guaranteed for instrument lifetime.

  • Triple Cone Interface minimizes maintenance; only cone cleaning required.

  • Universal Cell designed for long-term use without frequent replacement.

Operating Conditions

Temperature: 15 and 30 °C (59 - 86 °F) optimal, 3 °C (5 °F) rate of change.
Humidity: 20 - 80% (non-condensing)

Power and Cooling


  • Power: 16 A max continuous, 50/60 Hz operating frequency.

  • Cooling Water: 18 °C supply temperature, 3.8 L/min (min) / 4.7 L/min (typical), 413 ± 14 kPa pressure.

  • Optional GreenCT™ Cooling System for energy-efficient cooling.

Dimensions and Footprint

Width: 81 cm (32 in.)
Height: 73 cm (29 in.)
Depth: 72 cm (28 in.)
Weight: 150 kg (330 lb.)

GENERAL INFORMATION

Brand and Model

PerkinElmer NexION® 1100 ICP Mass Spectrometer

Documentation and Support

The sources include various application notes, brochures, case studies, flyers, guides, product notes, regulatory compliance certifications, technical notes, videos, and webinars related to the NexION 1100 ICP-MS.

Compatibility and Connectivity

Compatible with various accessories and peripherals, including autosamplers, high throughput systems, and flow injection modules from PerkinElmer, ESI, and CETAC.

Configuration and Options

Single gas channel can be upgraded to two or three channels for enhanced interference removal capability.
Peltier Cooler (PC3) can be added for analyzing organic solvents.

Licensing and Certification


  • CE Mark certified

  • Meets EN 61010-1:2010, EN 61010-2-081

  • Compliant with European EMC Directive 2014/30/EU

  • Fulfills EN 61326-1:2013

  • WEEE Directive 2012/19/EU

  • RoHS 2.68 compliance

Cost and Operational Expenses

Information not available in the sources.

PerkinElmer NexION 5000 Model B

PerkinElmer NexION 5000 Model B

Sign in to view price

$45IC6V

PERFORMANCE

Mass Accuracy

<0.7 atomic mass units (amu), ensuring high mass accuracy.

Resolution

<0.7 amu1

Sensitivity

The instrument delivers exceptionally low background equivalent concentrations (BECs) and outstanding detection limits, key to ensuring accurate, repeatable results.

Speed

Equipped with a Discrete Dynode Detector capable of fast data acquisition rates, essential for applications involving the analysis of transient signals.

Dynamic Range

1014

MASS RANGE AND ANALYTE DETECTION

Mass Range

The system's quadrupole mass filter allows for a broad mass range analysis, accommodating various elemental applications.

Detection Limit

Provides outstanding detection limits, essential for ultra-trace elemental applications.

Detector

Utilizes a Discrete Dynode Detector designed for rapid signal processing and high sensitivity.

IONIZATION, SOURCE AND INTERFACE

Ionization Method

Inductively Coupled Plasma (ICP)

Ion Source

Features an inductively coupled plasma (ICP) ion source, providing robust and efficient ionization of samples.

Interface

Triple Cone Interface with patent-pending OmniRing™

Gas Flow and Requirements

Operates with argon gas for plasma generation; specific flow rates and additional gas requirements depend on the application and are detailed in the user manual.

MASS ANALYZER

Mass Analyzer

Multi-Quadrupole

Quadrupole

Four Quadrupoles:

Quadrupole Ion Deflector
Transmission Analyzer Quadrupole
Quadrupole Universal Cell
Transmission Analyzer Quadrupole 2

CHROMATOGRAPHY AND SAMPLE HANDLING

Chromatography

Can be coupled with chromatographic systems for speciation studies, enhancing analytical capabilities.

Sample Handling

Offers customizable sample introduction systems to accommodate various sample types and matrices.

Injection System

Compatible with various injection systems, including autosamplers, to facilitate automated sample introduction.

DATA ACQUISITION AND ANALYSIS

Data Acquisition

Controlled by Syngistix™ for ICP-MS software, providing automated and user-friendly workflows with a contemporary user interface.

Data Analysis

The Syngistix™ software offers comprehensive data analysis tools, including qualitative and quantitative analysis, calibration, and reporting features.

AUTOMATION AND SOFTWARE

Automation

Supports automation through compatible autosamplers and software-controlled operations, enhancing laboratory efficiency.

Software

Syngistix™ for ICP-MS software (v. 3.0 or higher)

OPERATIONAL FEATURES

Ease of Use

External status lighting provides easy visibility of state of analysis.

Maintenance and Durability

Low maintenance for greater uptime:

Triple Cone Interface with patent-pending OmniRing™ combined with Quadrupole Ion Deflector deliver no maintenance beyond cones.

34 MHz free-running RF generator - plasma is generated by the LumiCoil™ RF load coil which is passively cooled by the extraction and requires no water or gas cooling.

Operating Conditions

Designed to operate under standard laboratory conditions; specific environmental requirements are provided in the user manual.

Power and Cooling

Equipped with a 34 MHz free-running RF generator; the plasma is generated by the unique LumiCoil™ RF load coil, which is air-cooled, eliminating the need for water or gas cooling.

Dimensions and Footprint

Depth: 85.0 cm
Height: 85.0 cm
Width: 114.0 cm
Weight: 191.0 kg

GENERAL INFORMATION

Brand and Model

PerkinElmer NexION® 5000 Multi-Quadrupole ICP-MS

Documentation and Support

Comprehensive documentation and support are available, including user manuals, application notes, and technical support services.

Compatibility and Connectivity

Features external status lighting for easy visibility of the state of analysis, optimizing efficiencies.

Configuration and Options

Available in Cleanroom and Non-Cleanroom models

Licensing and Certification

Certified to be able to be upgraded to meet SEMI S2/S8 (emergency button), delivering ease of integration in cleanroom facilities.

Cost and Operational Expenses

For detailed information on cost and operational expenses, it is recommended to contact PerkinElmer directly or consult with authorized distributors.