PERFORMANCE

Mass Accuracy
Resolution
Sensitivity
Speed
Dynamic Range

MASS RANGE AND ANALYTE DETECTION

Mass Range
Detection Limit
Detector

IONIZATION, SOURCE AND INTERFACE

Ionization Method
Ion Source
Interface
Gas Flow and Requirements

MASS ANALYZER

Mass Analyzer
Quadrupole

CHROMATOGRAPHY AND SAMPLE HANDLING

Chromatography
Sample Handling
Injection System

DATA ACQUISITION AND ANALYSIS

Data Acquisition
Data Analysis

AUTOMATION AND SOFTWARE

Automation
Software

OPERATIONAL FEATURES

Ease of Use
Maintenance and Durability
Operating Conditions
Power and Cooling
Dimensions and Footprint

GENERAL INFORMATION

Brand and Model
Documentation and Support
Compatibility and Connectivity
Configuration and Options
Licensing and Certification
Cost and Operational Expenses
Waters RADIAN ASAP Direct Mass Detector

Waters RADIAN ASAP Direct Mass Detector

Sign in to view price

$DCI1MZ

PERFORMANCE

Mass Accuracy

Not specified

Resolution

Single quadrupole analyzer with a pre-filter maximizes resolution and transmission of ions.

Sensitivity

Dual off-axis ion guides provide greater sensitivity by eliminating neutral species.

Speed

30-second analysis
Rapid triage of seized drug materials
Real-time sample analysis

Dynamic Range

Not specified

MASS RANGE AND ANALYTE DETECTION

Mass Range

Not specified

Detection Limit

Not specified

Detector

Low-noise, off-axis, long-life photomultiplier detector.

IONIZATION, SOURCE AND INTERFACE

Ionization Method

Integrated ASAP source (Atmospheric Pressure Sample Analysis Probe).

Ion Source

Pre-optimized ASAP source.

Interface

Not specified

Gas Flow and Requirements

Includes a de-clustering cone gas.

MASS ANALYZER

Mass Analyzer

Single quadrupole analyzer with a pre-filter.

Quadrupole

Single quadrupole mass detector.

CHROMATOGRAPHY AND SAMPLE HANDLING

Chromatography

Designed for direct analysis without the need for separation.

Sample Handling

Samples are loaded directly onto a capillary.

Injection System

Direct sample introduction via the ASAP probe.

DATA ACQUISITION AND ANALYSIS

Data Acquisition

Allows real-time sample analysis.

Data Analysis

LiveID™ Software enables real-time classification of samples
Spectral library matching

AUTOMATION AND SOFTWARE

Automation

Automated mass calibration and resolution verification
Automated diagnostics, checks, and alerts

Software

Supported on MassLynx™
Includes LiveID™ and IonLynx software

OPERATIONAL FEATURES

Ease of Use

Easy access to MS technology
Simple to operate with minimal training

Maintenance and Durability

Long-life photomultiplier detector
Tool-free access to user-serviceable elements

Operating Conditions

Temperature control programmable as isothermal, ballistic ramp, or stepped temperature profile.

Power and Cooling

Power supply: 100–240 V AC, 50/60 Hz.

Dimensions and Footprint

Width: 34.4 cm
Height: 27.1 cm
Depth: 73.0 cm
Weight: 34 kg

GENERAL INFORMATION

Brand and Model

Brand: Waters Corporation
Model: RADIAN ASAP

Documentation and Support

Waters Corporation contact information
Website: waters.com/RADIAN

Compatibility and Connectivity

Supported on MassLynx™
No detailed information available on other connectivity options.

Configuration and Options

Available in Performance and Standard system configurations.

Licensing and Certification

Regulatory approvals: CE, CB, NRTL (CAN/US), RCM.

Cost and Operational Expenses

Designed for low-cost analysis.
Specific cost figures not provided.

Shimadzu On-Column Derivatization GC-MS System

Shimadzu On-Column Derivatization GC-MS System

Sign in to view price

$4HNP81

PERFORMANCE

Mass Accuracy

±0.1 Da

Resolution

0.1 Da

Sensitivity

10 fg (femtogram)

Speed

Significantly shortened derivatization time due to on-column derivatization.

Dynamic Range

106

MASS RANGE AND ANALYTE DETECTION

Mass Range

1 - 1000 amu

Detection Limit

0.05 ng

Detector

Electron Multiplier (EM)

IONIZATION, SOURCE AND INTERFACE

Ionization Method

Electron Impact (EI)

Ion Source

Standard EI source

Interface

Direct inlet interface

Gas Flow and Requirements

1.5 - 2.0 mL/min (Helium)

MASS ANALYZER

Mass Analyzer

Quadrupole

Quadrupole

3-stage quadrupole

CHROMATOGRAPHY AND SAMPLE HANDLING

Chromatography

Gas Chromatography

Sample Handling

Direct analysis of extracted urine samples without additional pretreatment.

Injection System

Auto-injector AOC-30i with 2-step injection.

DATA ACQUISITION AND ANALYSIS

Data Acquisition

High-speed data acquisition (10 Hz)

Data Analysis

Shimadzu LabSolutions

AUTOMATION AND SOFTWARE

Automation

Automatic on-column derivatization using the AOC-30i auto-injector and the 2-step injection feature of the LabSolutions GCMS system.

Software

LabSolutions GCMS (requires specific versions for 2-step injection).
Optionally, GCMSsolution software can be used, but it requires additional software for 2-step injection.

OPERATIONAL FEATURES

Ease of Use

On-column derivatization simplifies sample preparation and reduces analysis time.

Maintenance and Durability

High durability, low maintenance needs

Operating Conditions

10°C to 40°C (ambient temperature)

Power and Cooling

100 - 240 V, 50/60 Hz, Forced air cooling

Dimensions and Footprint

630 mm (W) x 800 mm (D) x 420 mm (H)

GENERAL INFORMATION

Brand and Model

Analysis of phenethylamine drugs, such as methamphetamine and MDMA, in urine samples.

Documentation and Support

Shimadzu On-Column Derivatization GC-MS System, specifically compatible with GCMS-QP2050 and GCMS NX series.

Compatibility and Connectivity

USB, Ethernet, RS-232

Configuration and Options

Compatible with AOC-20i + 20sU, AOC-30i, and AOC-30i + 20 sU autoinjector and sampler configurations.

Licensing and Certification

CE, UL, RoHS compliant

Cost and Operational Expenses

Varies, typically high initial cost, low operational expenses