You have chosen to compare
PERFORMANCE
Mass Accuracy
Resolution
Sensitivity
Speed
Dynamic Range
MASS RANGE AND ANALYTE DETECTION
Mass Range
Detection Limit
Detector
IONIZATION, SOURCE AND INTERFACE
Ionization Method
Ion Source
Interface
Gas Flow and Requirements
MASS ANALYZER
Mass Analyzer
Quadrupole
CHROMATOGRAPHY AND SAMPLE HANDLING
Chromatography
Sample Handling
Injection System
DATA ACQUISITION AND ANALYSIS
Data Acquisition
Data Analysis
AUTOMATION AND SOFTWARE
Automation
Software
OPERATIONAL FEATURES
Ease of Use
Maintenance and Durability
Operating Conditions
Power and Cooling
Dimensions and Footprint
GENERAL INFORMATION
Brand and Model
Documentation and Support
Compatibility and Connectivity
Configuration and Options
Licensing and Certification
Cost and Operational Expenses

Bruker microflex® LRF
PERFORMANCE
Mass Accuracy
Increased mass accuracy delivered through proprietary PAN pulsed ion extraction, an independent reflector power supply, integrated MCP detector and high-precision digital converters.
Resolution
Best mass resolution in positive and negative ionization modes of a bench-top system.
Sensitivity
Unmatched sensitivity provided by a gridless reflector and proprietary AnchorChip technology.
Speed
Utilizes a 60 Hz nitrogen laser for rapid data acquisition.
Dynamic Range
Highest dynamic range.
MASS RANGE AND ANALYTE DETECTION
Mass Range
Capable of analyzing a broad mass range, accommodating various sample types.
Detection Limit
Offers high sensitivity, enabling detection of low-abundance analytes.
Detector
Linear or reflector.
Saturation free detector technology enables superior performance for high-mass detection.
IONIZATION, SOURCE AND INTERFACE
Ionization Method
Positive and negative ion modes.
MALDI.
Ion Source
microScout ion source.
60 Hz N2-Cartridge-Laser including variable power attenuator and UV optics.
Interface
Features user-friendly software for intuitive data acquisition and analysis.
Gas Flow and Requirements
Integrated oil-free vacuum system with a 70 L/sec turbo-molecular pump and diaphragm pump.
Specific gas flow requirements not specified.
MASS ANALYZER
Mass Analyzer
TOF.
Quadrupole
Not applicable.
Employs MALDI-TOF mass spectrometry without a quadrupole mass filter.
CHROMATOGRAPHY AND SAMPLE HANDLING
Chromatography
Not applicable.
Utilizes MALDI ionization, which does not require chromatographic separation.
Sample Handling
Uses the exact dimensions of 1/4 microtiter plate with a medium area target plate (54 mm x 36 mm).
Allows compatibility with MTP formats using pipetting robots.
Injection System
- MicroScout Ion Source: Compatible with 54 mm x 36 mm target plates.
- Automated Sample Introduction: Streamlined workflow efficiency.
DATA ACQUISITION AND ANALYSIS
Data Acquisition
Equipped with a 60 Hz nitrogen laser and advanced detector technology for efficient data collection.
Data Analysis
PolyTools software solution produces polymer structural information.
AUTOMATION AND SOFTWARE
Automation
Supports automated sample handling and data processing for high-throughput applications.
Software
PolyTools.
OPERATIONAL FEATURES
Ease of Use
Intuitive operation makes the system ideal for non-expert users and busy multi-instrument laboratories.
Easy to use bench-top instrument which provides answers for analysis tasks in no time.
Maintenance and Durability
- Oil-Free Vacuum System: Robust and maintenance-free.
- Stable Ion Generation: Ensures maximum uptime for multi-user labs.
- Pumping System: Includes vacuum control unit, 70 l/sec turbo pump, and diaphragm pump.
Operating Conditions
Designed for robust operation in standard laboratory environments.
Specific conditions not specified.
Power and Cooling
Features an integrated oil-free vacuum system for quiet operation.
Specific power and cooling requirements not specified.
Dimensions and Footprint
Benchtop.
GENERAL INFORMATION
Brand and Model
Bruker microflex® LRF.
Documentation and Support
Extensive customer support is provided through a network of sales and service offices and representatives throughout the world.
Compatibility and Connectivity
Compatible with various laboratory automation systems and software platforms for seamless integration into diverse workflows.
Configuration and Options
Offers linear and reflector modes of operation.
Accommodating a wide range of analytical applications.
Licensing and Certification
Specific licensing and certification details not specified.
Compliance with standard laboratory regulations implied.
Cost and Operational Expenses
Designed for cost-effective operation with minimal maintenance requirements.
Specific cost details not specified.

Shimadzu GCMS-QP2020 NX
PERFORMANCE
Mass Accuracy
±0.1 amu
Resolution
0.1 amu
Sensitivity
High level of sensitivity
Speed
High-speed scans of 10,000 u/sec or faster.
Dynamic Range
10^6
MASS RANGE AND ANALYTE DETECTION
Mass Range
1 – 1,000 amu
Detection Limit
10 fg (for selected ions)
Detector
High-performance detector
IONIZATION, SOURCE AND INTERFACE
Ionization Method
EI (Electron Ionization)
CI (Chemical Ionization)
Ion Source
Direct sample injection (DI)
Smart EI/CI ion source
Interface
EI (Electron Impact)
CI (Chemical Ionization)
Gas Flow and Requirements
Optimized Vacuum Performance: Large-capacity differential exhaust turbomolecular pump supports all carrier gases (H₂, N₂) for ideal MS conditions.
Precise Control: High-performance Advanced Flow Controller (AFC) ensures accuracy.
Efficient Separation: Differential exhaust method maintains independent vacuums for the ion source and quadrupole.
MASS ANALYZER
Mass Analyzer
Quadrupole Mass Spectrometer
Quadrupole
Quadrupole Mass Spectrometer
CHROMATOGRAPHY AND SAMPLE HANDLING
Chromatography
Gas Chromatography
Sample Handling
ClickTek™ lever allows tool-free opening and closing of the injection port to replace the insert.
Split line filter can be replaced without tools.
Injection System
Injection port
DATA ACQUISITION AND ANALYSIS
Data Acquisition
Smart SIM™, which simplifies and automates method creation.
High-speed data acquisition.
Quick-CI can perform collection consecutively in EI and CI modes.
Data Analysis
LabSolutions Insight™ software greatly reduces the time needed for data analysis.
GCMSsolution™ software.
AUTOMATION AND SOFTWARE
Automation
The system features automated technology, including automatic carrier gas leak checks, rod bias voltage optimization during high-speed data acquisition, and Smart SIM™ for automated method creation. The AART function estimates target component retention times using retention indices and an alkane standard mix.
Software
LabSolutions Insight™ software
GCMSsolution™ software
MassWorks software
Smart SIM™
LabSolutions™ DB/CS
EZGC Method Translator (By Restek)
OPERATIONAL FEATURES
Ease of Use
Intuitive Software & Easy Maintenance: User-friendly interface with ClickTek™ lever for tool-free injection port access.
Safe & Efficient: Easy sTop function allows maintenance without releasing vacuum.
Optimized Workflow: Active Time Management schedules maintenance, with real-time tracking for analysis & service times.
Reliable Results: Effortless peak correction ensures repeatable quantitative analysis.
Maintenance and Durability
Robustness.
Filament and ion source box separation, along with a shield that blocks radiant heat from the filament, results in long-term stability.
The system can be safely operated using carrier gases other than helium, such as hydrogen or nitrogen.
Operating Conditions
Temperature: 0 – 40°C, Humidity: ≤ 85% RH
Power and Cooling
Three oven cooling rate levels can be specified to minimize damage to column liquid phases and maximize service life.
Dimensions and Footprint
310 mm (W) × 592 mm (D) × 484 mm (H)
GENERAL INFORMATION
Brand and Model
Shimadzu GCMS-QP2020 NX Gas Chromatograph Mass Spectrometer
Documentation and Support
Brochures, applications, technical documents, and manuals are available.
Compatibility and Connectivity
Carrier Gas Compatibility: Supports hydrogen and nitrogen.
Safety Feature: Optional hydrogen sensor available.
Library Support: Compatible with NIST, Wiley, and GC/MS MPW DRUG spectral libraries; allows private library creation.
Configuration and Options
Twin Line MS System: Supports dual narrow-bore capillary columns.
Advanced Inlet Options: DI-2010, SMCI, OPTIC-4, and HS-20 NX.
Additional Systems: TD-30 (thermal desorption, pyrolysis), AOC-6000 Plus (autosampler), Py-Screener™ (phthalate screening), and GC/MS Off-Flavor Analyzer.
Licensing and Certification
CE, RoHS, UL
Cost and Operational Expenses
Using hydrogen or nitrogen as carrier gases reduces operating costs.
Nitrogen is approximately 10 times less expensive than helium.

PerkinElmer QSight® 220 Multi-Opt Dual Source System
PERFORMANCE
Mass Accuracy
±0.1 amu
Resolution
0.7 amu
Sensitivity
High level of sensitivity
Speed
20,000 u/s
Dynamic Range
10 orders of magnitude
MASS RANGE AND ANALYTE DETECTION
Mass Range
10 to 2000 amu
Detection Limit
Low ppt (parts per trillion)
Detector
Single Quadrupole Ion Detector
IONIZATION, SOURCE AND INTERFACE
Ionization Method
ESI or APCI2
Ion Source
Dual Source technology with two independent probes for true multiplexing
Interface
Laminar Flow Ion Guide™ for highly efficient field-free transmission, providing virtually no maintenance requirements
Gas Flow and Requirements
0.5 to 2 L/min (helium)
MASS ANALYZER
Mass Analyzer
Quadrupole
Quadrupole
Triple quadrupole
CHROMATOGRAPHY AND SAMPLE HANDLING
Chromatography
LC
Sample Handling
Liquid and Solid Sample Introduction
Injection System
AutoSampler
Manual Injection
DATA ACQUISITION AND ANALYSIS
Data Acquisition
Continuous or Time-Sliced Acquisition
Data Analysis
PerkinElmer LabSolutions™ Software
AUTOMATION AND SOFTWARE
Automation
Yes (with Autosampler)
Software
Simplicity™ 3Q Software
OPERATIONAL FEATURES
Ease of Use
Easy-to-learn and use
Maintenance and Durability
StayClean™ technology dramatically reduced source cleaning and maintenance
Operating Conditions
15°C to 35°C, 10-90% RH
Power and Cooling
100-240 V AC, Air-cooled
Dimensions and Footprint
60 cm x 40 cm x 50 cm (W x D x H)
GENERAL INFORMATION
Brand and Model
PerkinElmer QSight® 220 LC/MS/MS14
Documentation and Support
Online support
Manuals
Technical Support
Compatibility and Connectivity
USB
Ethernet
RS-232
Configuration and Options
Multiple Ionization Sources
Dual Source Configurations
Licensing and Certification
CE Mark
ISO 9001
Cost and Operational Expenses
Contact for Pricing and Operational Costs

Shimadzu LabSolutions GCMS
PERFORMANCE
Mass Accuracy
±0.1 Da (depending on conditions)
Resolution
0.1 Da (depending on settings)
Sensitivity
S/N ratio > 1000:1
Speed
The software enables simultaneous GC and MS acquisition and data analysis with ease. It includes a time management function that estimates the instrument startup and finishing times of consecutive analyses
Dynamic Range
> 107
MASS RANGE AND ANALYTE DETECTION
Mass Range
10 amu to 1050 amu
Detection Limit
< 10 fg (depending on ion type)
Detector
Electron Multiplier Detector (EMD)
IONIZATION, SOURCE AND INTERFACE
Ionization Method
EI (Electron Ionization)
Ion Source
EI source
Interface
Standard EI interface (quadrupole)
Gas Flow and Requirements
Carrier Gas: He or N2
Flow rate: 1-2 mL/min
MASS ANALYZER
Mass Analyzer
Quadrupole Mass Spectrometer
Quadrupole
Yes
CHROMATOGRAPHY AND SAMPLE HANDLING
Chromatography
Gas Chromatography (GC)
Sample Handling
Liquid, solid, or gas samples
Injection System
Split/Splitless
PTV (Programmable Temperature Vaporization)
DATA ACQUISITION AND ANALYSIS
Data Acquisition
LabSolutions GCMS software integrates with the system to maximize the efficiency of the acquisition and data analysis workflow
Data Analysis
- LabSolutions Insight software reduces time for multisample quantitative analysis.
- Peakintelligence for GCMS shortens peak integration time and provides results quickly.
- LabSolutions allows data output in multiple formats and integrates with LIMS systems.
AUTOMATION AND SOFTWARE
Automation
Yes
Auto-sampler
Auto-Calibration
Software
LabSolutions GCMS software integrates with the system to maximize the efficiency of the acquisition and data analysis workflow
OPERATIONAL FEATURES
Ease of Use
- LabSolutions GCMS software optimizes acquisition and data analysis workflows.
- Automatically creates multicomponent analysis methods for increased efficiency.
- Time management function estimates instrument startup and finishing times for consecutive analyses.
- Optional automatic peak integration reduces integration time while maintaining high-quality results.
Maintenance and Durability
Low maintenance
Routine service required
Operating Conditions
Temperature range: 4°C to 45°C
Power and Cooling
100-240 V
Cooling: Optional Chiller
Dimensions and Footprint
Approx. 1100 x 650 x 800 mm (W x D x H)
GENERAL INFORMATION
Brand and Model
Shimadzu LabSolutions GCMS
Documentation and Support
Downloadable brochures
Applications
Technical documents
Manuals are available
Compatibility and Connectivity
Data obtained with LabSolutions can be output in a variety of formats, and can be coordinated with a host system such as a laboratory information management system (LIMS)
Configuration and Options
- System Linkage Option
- LabSolutions Insight Environmental Option
- LabSolutions i-QLinks
- LabSolutions Sync
- LabSolutions MD
Licensing and Certification
CE
RoHS
ISO 9001:2015
Cost and Operational Expenses
Variable based on configuration and usage