Agilent 6560 Ion Mobility LC/Q-TOF
The Agilent 6560 Ion Mobility LC/Q-TOF combines ion mobility and LC-MS for high-resolution analysis.
Features
- High resolution and sensitivity
- Integrated ion mobility spectrometry
- Advanced software for data analysis
- Seamless coupling with liquid chromatography for comprehensive analysis
Applications
- Proteomics
- Metabolomics
- Complex sample analysis
- Environmental testing
- Pharmaceutical analysis
Product Specifications
PERFORMANCE
Mass Accuracy
Positive: <1 ppm RMS
Resolution
Ion Mobility Resolution (FWHM): >200
TOF Mass Resolution (FWHM): > 42,000 at m/z 2,722 independent of acquisition rate
TOF Mass Resolution (FWHM): > 42,000 at m/z 2,722 independent of acquisition rate
Sensitivity
MS Sensitivity (positive): S/N (RMS) > 50:1. Measured with 1pg reserpine on column
Speed
MS Acquisition Rate: 50 spectra/second
MS/MS Acquisition Rate: 30 spectra/second
Up to 5 Hz acquisition rate can be used without compromising resolution for UHPLC compatibility
MS/MS Acquisition Rate: 30 spectra/second
Up to 5 Hz acquisition rate can be used without compromising resolution for UHPLC compatibility
Dynamic Range
5 Orders
MASS RANGE AND ANALYTE DETECTION
Mass Range
TOF Mass Range: m/z 20-20,000
Detection Limit
Low femtomolar (fM) to picomolar (pM)
Detector
Quadrupole Time-of-Flight (Q-TOF)
IONIZATION, SOURCE AND INTERFACE
Ionization Method
Electrospray Ionization (ESI), APCI
Ion Source
Dual-AJS
Dual-ESI
APCI
MultiMode (ESI+APCI)
GC/APCI
NanoESI
Dual-ESI
APCI
MultiMode (ESI+APCI)
GC/APCI
NanoESI
Interface
Jet Stream ion source
Gas Flow and Requirements
Nitrogen (N2), 10–20 L/min
MASS ANALYZER
Mass Analyzer
Quadrupole Time of Flight LC/MS
Quadrupole
Quad Resolution (FWHM): 1.3 Da (autotune)
Quadrupole Isolation Mass Range: m/z 20-4000
Quadrupole Isolation Mass Range: m/z 20-4000
CHROMATOGRAPHY AND SAMPLE HANDLING
Chromatography
The 6560C combines chromatography, ion mobility, and mass spectrometry
UHPLC
UHPLC
Sample Handling
Auto-sampler, direct injection
Injection System
Rheodyne Manual or Automated Injector
DATA ACQUISITION AND ANALYSIS
Data Acquisition
MassHunter
Data Analysis
MassHunter
MassHunter BioConfirm
MassHunter VistaFlux
Mass Profiler Professional
Classifier
Lipid Annotator
Agilent high resolution demultiplexing (HRdm 2.0) software
MassHunter BioConfirm
MassHunter VistaFlux
Mass Profiler Professional
Classifier
Lipid Annotator
Agilent high resolution demultiplexing (HRdm 2.0) software
AUTOMATION AND SOFTWARE
Automation
An automated workflow for the analysis of protein phosphorylation
Software
MassHunter
OPERATIONAL FEATURES
Ease of Use
User-friendly interface with touch screen and software control
Maintenance and Durability
Ventless Maintenance: VacShield Technology
Utilizes Agilent VacShield for vent-free capillary removal
Utilizes Agilent VacShield for vent-free capillary removal
Operating Conditions
Temperature range: 10–40°C, Humidity: 20–80% RH
Power and Cooling
Power: 100–240 V, Cooling: Active or passive depending on configuration
Dimensions and Footprint
Approx. 55 x 55 x 30 cm (WxDxH)
GENERAL INFORMATION
Brand and Model
Agilent 6560C ion mobility Q-TOF LC/MS system
Agilent 6560 ion mobility LC/Q-TOF
Agilent 6560 ion mobility LC/Q-TOF
Documentation and Support
Targeted Data Mining and Annotation of Untargeted High-Resolution Lipidomics Data application note.
Exact Structure Identification of Isomeric N-Glycans by High-Resolution Ion Mobility LC/Q-TOF application note.
Structural Analysis of the Multimers of Bovine Serum Albumin by Ion Mobility Mass Spectrometry application note.
Examining the Structural Influence of Site-Specific Phosphorylation by Ion Mobility Mass Spectrometry application note.
MassHunter Data Acquisition for LC/TOF and LC/Q-TOF Familiarization Guide.
MassHunter Workstation 11.0 for LC/TOF and LC/Q-TOF Installation Guide.
MassHunter Networked Workstation Functional Design Specifications.
Exact Structure Identification of Isomeric N-Glycans by High-Resolution Ion Mobility LC/Q-TOF application note.
Structural Analysis of the Multimers of Bovine Serum Albumin by Ion Mobility Mass Spectrometry application note.
Examining the Structural Influence of Site-Specific Phosphorylation by Ion Mobility Mass Spectrometry application note.
MassHunter Data Acquisition for LC/TOF and LC/Q-TOF Familiarization Guide.
MassHunter Workstation 11.0 for LC/TOF and LC/Q-TOF Installation Guide.
MassHunter Networked Workstation Functional Design Specifications.
Compatibility and Connectivity
Agilent partners with innovators who provide technologies and software that expand the core capabilities of the LC/Q-TOF portfolio.
Configuration and Options
Learn more about additional capabilities and visit the compatibility matrix to see which ones are offered for your LC/Q-TOF.
Licensing and Certification
CE, RoHS, FDA 21 CFR Part 11 compliance
Cost and Operational Expenses
Varies by region, high initial cost, consumables and maintenance cost considerations.