Thermofisher Element GD Plus™ GD-MS
Element GD Plus™ GD-MS offers high-sensitivity, high-precision trace element analysis in solid materials for research and industry.
Features
- Advanced ion optics for superior sensitivity and accuracy.
- High-speed analysis of bulk materials.
- Wide dynamic range to detect trace and major elements.
- User-friendly software for streamlined operation.
- Minimal sample preparation required.
Applications
- Quality control in metals and alloys.
- Trace elemental analysis in semiconductors.
- Research and development in materials science.
- Environmental monitoring of trace elements in solid samples.
Product Specifications
PERFORMANCE
Mass Accuracy
High mass resolution allows for accurate measurement of isotope signals, separating them from spectral interferences to produce clean elemental spectra.
Resolution
- Fixed Resolutions:
- ≥ 300
- ≥ 4,000
- ≥ 10,000
Sensitivity
>1 x 1010 Cps (1.6 x 10-9 A) for Copper Peak (Peak Height, Total Ion Current) in Medium Resolution.
Speed
Up to 5 samples/hr.
Dynamic Range
>1012 Linear with Automatic Cross Calibration.
MASS RANGE AND ANALYTE DETECTION
Mass Range
Capable of analyzing nearly the entire periodic table, covering concentrations from mg/L to sub pg/L, making it suitable for a wide range of applications.
Detection Limit
Parts per billion (ppb) level for many elements
Sub-ppm level limits of detection for CNO with optional CNO option.
Sub-ppm level limits of detection for CNO with optional CNO option.
Detector
Features a unique detection system combining a dual-mode Secondary Electron Multiplier (SEM) with a Faraday detector, extending the linear dynamic range by three orders of magnitude.
IONIZATION, SOURCE AND INTERFACE
Ionization Method
Glow discharge.
Ion Source
Glow discharge ion source
Fast-flow ion source
Unique ion source designed for high ion transmission.
Fast-flow ion source
Unique ion source designed for high ion transmission.
Interface
Equipped with a high-performance interface, including options like the Jet Interface with platinum-tipped cones for enhanced sensitivity.
Gas Flow and Requirements
Operates with argon gas for the plasma, with specific flow rates and purity requirements as per standard ICP-MS operations.
MASS ANALYZER
Mass Analyzer
GS Mass Spectrometer.
Quadrupole
Not applicable; the instrument employs a double-focusing magnetic sector field mass analyzer instead of a quadrupole.
CHROMATOGRAPHY AND SAMPLE HANDLING
Chromatography
Not applicable; the instrument is designed for direct solid sample analysis and does not utilize chromatographic separation.
Sample Handling
Less sample preparation: no requirement for acid cleaning of high-purity samples
Dedicated workflow for sample preparation and analysis of low melting point metals.
Dedicated workflow for sample preparation and analysis of low melting point metals.
Injection System
Supports various injection systems tailored to specific applications, such as desolvating nebulizer systems for increased sensitivity.
DATA ACQUISITION AND ANALYSIS
Data Acquisition
Provides accurate and reliable quantitative multi-element analyses at trace levels, with high sensitivity and without complicated sample preparation.
Data Analysis
Determine elemental concentrations rapidly within a single scan without calibration standards (using standard RSF approach).
AUTOMATION AND SOFTWARE
Automation
Automatic cross-calibration between different detection modes.
Software
Includes specialized software for instrument control, data acquisition, and analysis, facilitating straightforward method development and operation.
OPERATIONAL FEATURES
Ease of Use
User-friendly source design: < 1 min sample exchange.
Maintenance and Durability
Built for robustness, capable of operating in 24/7 production control environments, with features that ensure long-term stability and minimal maintenance requirements.
Operating Conditions
Requires a controlled laboratory environment with stable temperature and humidity conditions, as per standard requirements for high-precision analytical instruments.
Power and Cooling
3-Phase, 230/400 V ± 10%, 50/60 Hz Fused 32 A / Phase.
Dimensions and Footprint
Unit Size: Each.
GENERAL INFORMATION
Brand and Model
Thermo Scientific™ Element GD Plus™ GD-MS.
Documentation and Support
Comprehensive support including user manuals, application notes, and access to technical support services.
Compatibility and Connectivity
Compatible with various sample introduction and separation systems; offers connectivity options for data management and integration with laboratory information management systems (LIMS).
Configuration and Options
Optional CNO option
Flexible anode diameter for advanced depth profiling.
Flexible anode diameter for advanced depth profiling.
Licensing and Certification
Complies with relevant industry standards and regulations; specific certifications can be provided upon request.
Cost and Operational Expenses
Pricing and operational costs vary based on configuration and application requirements; for detailed information, it is recommended to contact a sales representative or request a quote.