PerkinElmer GCMS 2400 System
High-precision GC-MS for reliable analysis across diverse industries.
Features
- High-performance gas chromatography and mass spectrometry integration
- Exceptional sensitivity and resolution for accurate analysis
- User-friendly software interface
- Durable and reliable for demanding laboratory environments
Applications
- Environmental testing
- Food and beverage analysis
- Pharmaceutical research and development
- Chemical and petrochemical analysis
Product Specifications
PERFORMANCE
Mass Accuracy
± 0.1 m/z over 48 hours
Resolution
Value: 1 amu (10% valley definition)
Precision: High
Separation Capability: Excellent
Precision: High
Separation Capability: Excellent
Sensitivity
EI Full Scan: 1 pg of Octafluoronaphthalene 1500:1
Positive CI Full Scan: 100 pg of Benzophenone 1200:1
Negative CI Full Scan: 1 pg of Octafluoronaphthalene 10,000:1
Positive CI Full Scan: 100 pg of Benzophenone 1200:1
Negative CI Full Scan: 1 pg of Octafluoronaphthalene 10,000:1
Speed
Up to 12,500 amu/sec (Scan Rate)
100 points/sec (Acquisition Rate)
100 points/sec (Acquisition Rate)
Dynamic Range
Value: 3-4 orders of magnitude
Sensitivity: Wide-spectrum
Range Performance: Comprehensive
Sensitivity: Wide-spectrum
Range Performance: Comprehensive
MASS RANGE AND ANALYTE DETECTION
Mass Range
1.0 – 1,200 u (amu)
Detection Limit
Value: 0.1-1 parts per billion (ppb)
Sensitivity: Ultra-trace
Detectability: Superior
Sensitivity: Ultra-trace
Detectability: Superior
Detector
Clarifi™ Detector
IONIZATION, SOURCE AND INTERFACE
Ionization Method
Electron Ionization (EI) and Chemical Ionization (CI)
Ion Source
PerkinElmer SMARTsource™
Interface
Type: Electron Impact (EI)
Ionization Modes: Single/Multiple
Compatibility: Universal
Ionization Modes: Single/Multiple
Compatibility: Universal
Gas Flow and Requirements
Maximum 5 mL/min helium (Carrier Gas Flow Rate)
MASS ANALYZER
Mass Analyzer
Solid metal quadrupole with pre-filter
Quadrupole
Mass Range: 10-550 m/z
Scanning Speed: 2-3 scans/second
Resolution: High-precision
Scanning Speed: 2-3 scans/second
Resolution: High-precision
CHROMATOGRAPHY AND SAMPLE HANDLING
Chromatography
Gas Chromatography
Sample Handling
Capacity: Multi-sample
Types: Liquid, Gas, Solid
Flexibility: Excellent
Types: Liquid, Gas, Solid
Flexibility: Excellent
Injection System
Modes: Split/Splitless
Volume Range: 0.1-2 µL
Precision: ±0.5%
Volume Range: 0.1-2 µL
Precision: ±0.5%
DATA ACQUISITION AND ANALYSIS
Data Acquisition
Full Scan
Selected Ion Monitoring (SIM)
Simultaneous Full-Scan Selected Ion Monitoring (SIFI)
Selected Ion Monitoring (SIM)
Simultaneous Full-Scan Selected Ion Monitoring (SIFI)
Data Analysis
Environmental, Forensic, Qualitative and Quantitative applications
AUTOMATION AND SOFTWARE
Automation
Sample Tray Capacity: 50-100 Samples
Run Sequence: Programmable
Unattended Operation: Full
Run Sequence: Programmable
Unattended Operation: Full
Software
SimplicityChrom™ Chromatography Data System (CDS) Software
OPERATIONAL FEATURES
Ease of Use
Detachable Touchscreen for Real-time Status Notification
SMARTsource Technology for Easy Maintenance
SimplicityChrom CDS Software
SMARTsource Technology for Easy Maintenance
SimplicityChrom CDS Software
Maintenance and Durability
SMARTsource Technology for Easy Maintenance
Marathon Filament for Ultimate Robustness
Marathon Filament for Ultimate Robustness
Operating Conditions
10 ˚C – 30 ˚C (Temperature)
20 – 80 % Non-condensing (Relative Humidity)
20 – 80 % Non-condensing (Relative Humidity)
Power and Cooling
120 VAC ± 10% @ 50/60 Hz ± 1% 1,000 VA
230 VAC ± 10% @ 50/60 Hz ± 1% 1,000 VA
230 VAC ± 10% @ 50/60 Hz ± 1% 1,000 VA
Dimensions and Footprint
48 CM X 31 CM X 65 CM (MS 2400 SQ Detector)
104.5 CM X 81 CM X 69 CM (GCMS 2400 System with AS 2400 Liquid Sampler)
104.5 CM X 81 CM X 69 CM (GCMS 2400 System with AS 2400 Liquid Sampler)
GENERAL INFORMATION
Brand and Model
PerkinElmer GCMS 2400 System MS25
Documentation and Support
Manual Complexity: Detailed
Technical Support: 24/7
Training: Included
Technical Support: 24/7
Training: Included
Compatibility and Connectivity
Network: Ethernet/USB
Data Export: Multiple Formats
LIMS Integration: Seamless
Data Export: Multiple Formats
LIMS Integration: Seamless
Configuration and Options
MS 2400 SQ T Detector
MS 2400 SQ C Detector
MS 2400 SQ C Detector
Licensing and Certification
Warranty: 1-2 years
Compliance: FDA/EPA
Calibration: Certified
Compliance: FDA/EPA
Calibration: Certified
Cost and Operational Expenses
Initial Investment: $100,000-$250,000
Annual Maintenance: $10,000-$20,000
Consumables: $5,000-$10,000/year
Annual Maintenance: $10,000-$20,000