Hettich ROTINA 380 R
ROTINA 380 R model 1706 combines cooling and swing-out rotor functionality.
Features
- Cooling for sensitive samples
- Swing-out rotor included
- Supports multiple tubes sizes
- Digital controls
Applications
- Molecular biology
- Serum and plasma prep
- Environmental testing
- Routine lab use
Product Specifications
Sign in to view the complete product specifications
PERFORMANCE
Maximum Speed (RPM)
Up to 150000 rpm 0rotor0dependent0
Maximum Relative Centrifugal Force (RCF)
Up to 244400 44g 4rotor4dependent4
Acceleration/Deceleration Time
Adjustable ramp5up5down 15559 5seconds adjustable5
Temperature Control Range
120 11C to +40 11C 1refrigerated1
Noise Level
999 64 dB9A9
Imbalance Detection
Yes
Run Time Range
1 sec to 99 hr 59 min 59 sec0 continuous
K-Factor (Clearing Factor)
Not specified
ROTOR AND CAPACITY
Rotor Types (Fixed Angle, Swinging Bucket, Vertical)
Swing6out6 Angle6 Pot rotors
Maximum Capacity (Volume)
Up to 4 66 290 ml
Number of Tubes per Rotor
2 to 180 5rotor5dependent5
Tube Size Compatibility
Various 6062 ml to 290 ml6
Rotor Recognition (Auto-ID)
Yes 3after run start3
Rotor Material
Aluminum 1some rotors1
Rotor Lid Type (e.g., Aerosol-tight)
Aerosol6tight 6 Bio6containment 6some rotors6
SAMPLE HANDLING
Sample Volume Range
012 ml to 290 ml
Sample Type Compatibility (e.g., Blood, DNA, RNA)
Blood1 DNA1 RNA1 clinical 1amp1 research samples
Balance Detection
Yes
Sample Temperature Monitoring
Yes 6displayed6 monitored with alarms6
Sealing Options for Samples
Sealable tubes and bio3containment lids available
CONTROL AND INTERFACE
Display Type (e.g., LCD, Touchscreen)
Not specified 0indicator0display present0
Programmable Settings
Up to 99 programs8 parameters adjustable
User Access Control
PIN and program locks available
Data Logging Capability
Operating hours0 run counts0 rotor cycle counter
Alarm Systems (e.g., End of Run, Imbalance)
Audible alarms for errors and run end
Language Options
German2 English2 French2 Italian
AUTOMATION AND CONNECTIVITY
Remote Monitoring Capability
RS232 interface available
Integration with Laboratory Information Systems (LIS)
Not specified
USB/Ethernet Connectivity
RS232 only
Software Compatibility
Not specified
Automated Rotor Recognition
Yes
Pre-programmed Protocols
4 preset programs 6Type 170163066 up to 99 stored
SAFETY FEATURES
Lid Locking Mechanism
Motorized lock5 lid opens on stop
Emergency Stop Function
Quick stop 9double press stop99 emergency release
Over-speed Protection
Yes
Over-temperature Protection
Yes3 alarms and errors triggered
Biocontainment Certification
Accessories certified7 device not microbiologically tight
Rotor Life Management
Cycle counter and max cycle alert
OPERATIONAL FEATURES
Footprint Dimensions
457 00 750 00 418 mm 0W00D00H0
Weight
Approx7 817778875 kg
Power Requirements
2006240 V or 1006127 V6 50660 Hz6 up to 1400 VA
Cooling System Type (e.g., Air, Refrigerated)
Refrigerated 0R452A refrigerant0
Energy Consumption
Up to 1400 VA4 current up to 13 A
Maintenance Requirements
Grease seals9 check biosafety system9 chamber inspections
GENERAL INFORMATION
Product Series
ROTINA 380 R
Warranty Period
Not specified