Thermofisher iCAP™ TQ ICP-MS
iCAP™ TQ ICP-MS offers superior sensitivity, accuracy, and performance for high-precision elemental and isotopic analysis.
Features
- Triple quadrupole technology for enhanced interference removal
- High sensitivity and precision in trace element analysis
- User-friendly software for efficient workflows
- Robust design for long-term reliability
- Optimized for a wide range of sample matrices
Applications
- Environmental analysis
- Food safety and quality testing
- Pharmaceutical development and quality control
- Geochemical and isotopic studies
- Industrial and metallurgical testing
Product Specifications
PERFORMANCE
Mass Accuracy
Achieves a mass accuracy specification of 0.5 ppm, ensuring precise isotope ratio measurements.
Resolution
Provides unit mass resolution, allowing for effective separation of analyte peaks from potential interferences.
Sensitivity
> 60 kcps/ppb for 7Li
>170 kcps/ppb for 59Co
>420 kcps/ppb for 115In
>410 kcps/ppb for 238U
>170 kcps/ppb for 59Co
>420 kcps/ppb for 115In
>410 kcps/ppb for 238U
Speed
Capable of rapid multi-element analysis with dwell times as short as 100 microseconds, enhancing throughput for high-sample-volume laboratories.
Dynamic Range
Offers a linear dynamic detection range greater than 10 orders of magnitude for a single isotope, accommodating a wide range of analyte concentrations without compromising accuracy.
MASS RANGE AND ANALYTE DETECTION
Mass Range
Covers a mass range suitable for most applications, enabling analysis of a broad spectrum of elements.
Detection Limit
See Table 2 for detection limits for silicon.
Detector
Equipped with a long-lifetime detector designed specifically for ICP-MS requirements, featuring automated optimization of operating voltages and cross-calibration to enhance data quality.
IONIZATION, SOURCE AND INTERFACE
Ionization Method
Inductively coupled plasma (ICP)
Ion Source
Utilizes an inductively coupled plasma (ICP) ion source, providing efficient ionization of a wide range of elements.
Interface
Features a robust interface with nickel cones and a high-performance design to ensure efficient ion transmission and minimal maintenance.
Gas Flow and Requirements
Utilizes argon gas for plasma generation, with three mass flow controllers for precise regulation.
Optional additional mass flow controllers are available to accommodate specific application needs.
Optional additional mass flow controllers are available to accommodate specific application needs.
MASS ANALYZER
Mass Analyzer
Triple quadrupole
Quadrupole
Yes
CHROMATOGRAPHY AND SAMPLE HANDLING
Chromatography
Compatible with chromatography systems
Sample Handling
Compatible with automation and sample-handling systems
Injection System
Utilizes a glass concentric nebulizer with a default flow rate of 400 µL/min,
coupled with a quartz cyclonic spray chamber and a demountable quartz torch with a 2.5 mm ID injector,
providing efficient sample aerosol generation and transport.
coupled with a quartz cyclonic spray chamber and a demountable quartz torch with a 2.5 mm ID injector,
providing efficient sample aerosol generation and transport.
DATA ACQUISITION AND ANALYSIS
Data Acquisition
Managed through Qtegra™ Intelligent Scientific Data Solution™ (ISDS) software,
offering comprehensive control over instrument parameters and data collection,
with automated optimization routines to enhance data quality.
offering comprehensive control over instrument parameters and data collection,
with automated optimization routines to enhance data quality.
Data Analysis
Performed using integrated software tools within Qtegra™ ISDS,
facilitating detailed analysis of isotope ratios and elemental concentrations,
with features such as Reaction Finder Method Development Assistant to simplify method development.
facilitating detailed analysis of isotope ratios and elemental concentrations,
with features such as Reaction Finder Method Development Assistant to simplify method development.
AUTOMATION AND SOFTWARE
Automation
Compatible with automation systems
Software
Thermo Scientific™ Qtegra™ Intelligent Scientific Data Solution™ (ISDS)
OPERATIONAL FEATURES
Ease of Use
Easy to use, any analyst can operate it
Maintenance and Durability
Improved lifetime and reduced maintenance for high matrix samples
Operating Conditions
Designed to operate under standard laboratory conditions;
specific environmental requirements are not detailed but should align with typical laboratory standards for ICP-MS instruments.
specific environmental requirements are not detailed but should align with typical laboratory standards for ICP-MS instruments.
Power and Cooling
Requires appropriate power supply and cooling systems typical for high-precision mass spectrometers;
specific specifications are not detailed but should be consistent with standard laboratory infrastructure.
specific specifications are not detailed but should be consistent with standard laboratory infrastructure.
Dimensions and Footprint
The smallest triple quadrupole instrument on the market - this information is not from the provided sources and you may want to verify it independently.
GENERAL INFORMATION
Brand and Model
Thermo Scientific™ iCAP™ TQ ICP-MS
Documentation and Support
Comprehensive support and documentation are available through Thermo Fisher Scientific's official channels,
including detailed brochures and technical specifications.
including detailed brochures and technical specifications.
Compatibility and Connectivity
Compatible with alternative sampling devices such as lasers or chromatography
Configuration and Options
PLUS Torch, Cold Plasma lens kit
Licensing and Certification
Complies with international standards for laboratory instrumentation;
specific certifications are not detailed but can be obtained from the manufacturer.
specific certifications are not detailed but can be obtained from the manufacturer.
Cost and Operational Expenses
Pricing is available upon request;
operational expenses include routine maintenance, consumables, and potential software updates.
It's advisable to contact Thermo Fisher Scientific directly for detailed cost information tailored to your specific application needs.
operational expenses include routine maintenance, consumables, and potential software updates.
It's advisable to contact Thermo Fisher Scientific directly for detailed cost information tailored to your specific application needs.