Thermofisher Neoma™ Multicollector ICP-MS
Neoma™ ICP-MS delivers exceptional precision and sensitivity for isotope ratio analysis in advanced research.
Features
- High-precision isotope ratio measurements
- Superior sensitivity and resolution
- Flexible detector configurations
- Advanced signal processing technology
- User-friendly interface for streamlined operations
Applications
- Geochemical and geochronological research
- Environmental and climate studies
- Nuclear forensics
- Biomedical and pharmaceutical research
Product Specifications
PERFORMANCE
Mass Accuracy
Achieves a mass accuracy specification of 0.5 ppm, ensuring precise isotope ratio measurements.
Resolution
Low, medium, and high
XHR (Extra High Resolution) up to 15,000 with the XHR option
XHR (Extra High Resolution) up to 15,000 with the XHR option
Sensitivity
Greater than 1.5% for uranium and lead
Speed
Capable of high-precision isotope analysis with rapid switching between applications
Dynamic Range
6 Gcps (10^11 Ω)45
Extended dynamic range up to 60 Gcps
Extended dynamic range up to 60 Gcps
MASS RANGE AND ANALYTE DETECTION
Mass Range
From Li to U
Detection Limit
Jet Interface and desolvating nebulizer achieve >1.5% ion yield for uranium & lead, ensuring top-tier ICP-MS sensitivity.
Detector
11 moveable Faraday cups
1 central dual-mode detector (Faraday/SEM)
1 central dual-mode detector (Faraday/SEM)
IONIZATION, SOURCE AND INTERFACE
Ionization Method
Inductively coupled plasma (ICP)9
Ion Source
Robust iCAP Qnova ICP-MS source with a field-proven Ar ion source
Interface
Jet Interface
Gas Flow and Requirements
Utilizes argon for plasma generation with adaptable flow rates, ensuring robustness for varying sample matrices.
MASS ANALYZER
Mass Analyzer
Magnetic sector
Quadrupole
Retarding Potential Quadrupole (RPQ)
CHROMATOGRAPHY AND SAMPLE HANDLING
Chromatography
Gas chromatography10
Sample Handling
- Supports wet or dry plasma
- Compatible with laser ablation
- Enables hydride generation
- Integrates with gas chromatography
Injection System
Compatible with both wet and dry plasma introduction systems, including desolvating nebulizer systems to enhance sensitivity.
DATA ACQUISITION AND ANALYSIS
Data Acquisition
Time-resolved data acquisition and analysis (TRA)
Data Analysis
Comprehensive data evaluation, including transient signal analysis
AUTOMATION AND SOFTWARE
Automation
Workflow support and automation
Software
Thermo Scientific™ Qtegra™ Intelligent Scientific Data Solution™ (ISDS) Software
OPERATIONAL FEATURES
Ease of Use
One-click "Get Ready" function, simple dynamic workflow and an intuitive user interface
Maintenance and Durability
Features a robust design with components like the iCAP Qnova ICP-MS source, ensuring durability.
The system includes user-friendly software for streamlined workflows and enhanced productivity.
The system includes user-friendly software for streamlined workflows and enhanced productivity.
Operating Conditions
Designed to operate under standard laboratory conditions.
Specific environmental requirements are not detailed but should align with typical laboratory standards for ICP-MS instruments.
Specific environmental requirements are not detailed but should align with typical laboratory standards for ICP-MS instruments.
Power and Cooling
Requires appropriate power supply and cooling systems typical for high-precision mass spectrometers.
Specific specifications are not detailed but should be consistent with standard laboratory infrastructure.
Specific specifications are not detailed but should be consistent with standard laboratory infrastructure.
Dimensions and Footprint
Designed to fit standard laboratory environments.
Specific dimensions are not provided but should be confirmed with the manufacturer for precise planning.
Specific dimensions are not provided but should be confirmed with the manufacturer for precise planning.
GENERAL INFORMATION
Brand and Model
Thermo Scientific™ Neoma™ Multicollector ICP-MS
Documentation and Support
Comprehensive support and documentation are available through Thermo Fisher Scientific's official channels, including detailed brochures and technical specifications.
Compatibility and Connectivity
Integration of first and third-party peripherals such as desolvating nebulization, laser ablation, and chromatography systems
Configuration and Options
- Upgrade pathway to Thermo Scientific™ Neoma™ MS/MS MC-ICP-MS
- MIC packages
- XHR
- RPQ
Licensing and Certification
Complies with international standards for laboratory instrumentation.
Specific certifications are not detailed but can be obtained from the manufacturer.
Specific certifications are not detailed but can be obtained from the manufacturer.
Cost and Operational Expenses
Pricing is available upon request.
Operational expenses include routine maintenance, consumables, and potential software updates.
It's advisable to contact Thermo Fisher Scientific directly for detailed cost information tailored to your specific application needs.
Operational expenses include routine maintenance, consumables, and potential software updates.
It's advisable to contact Thermo Fisher Scientific directly for detailed cost information tailored to your specific application needs.