Shimadzu Py-Screener Ver. 2
Shimadzu Py-Screener Ver. 2: Advanced GC-MS screening tool for high sensitivity, ease of use, and reliability.
Features
- Advanced sample screening capability
- High sensitivity detection
- User-friendly interface
- Compatible with Shimadzu GC-MS systems
- High throughput and reliability
Applications
- Environmental analysis
- Food and beverage testing
- Pharmaceutical and chemical industry analysis
- Forensic analysis
- Research and development
Product Specifications
PERFORMANCE
Mass Accuracy
±0.5 Da
Resolution
≥100,000 (FWHM)
Sensitivity
<10 fg (at m/z 200)
Speed
The new 22-minute method simultaneously inspects 7 phthalate esters and brominated flame retardants, cutting the time from 35 minutes. A high-speed method further shortens phthalate ester inspection.
Dynamic Range
6 orders of magnitude
MASS RANGE AND ANALYTE DETECTION
Mass Range
1 to 1000 m/z
Detection Limit
≤ 0.1 fg (depending on sample)
Detector
The system utilizes GC/MS for analysis, with a Mass Spectrometer (MS) serving as the detector.
IONIZATION, SOURCE AND INTERFACE
Ionization Method
Electron Impact (EI)
Chemical Ionization (CI)
Chemical Ionization (CI)
Ion Source
Heated EI and CI ion source
Interface
Direct inlet
Pneumatic nebulizer
Pneumatic nebulizer
Gas Flow and Requirements
10-20 L/min (for carrier gas)
2 L/min (for auxiliary gas)
2 L/min (for auxiliary gas)
MASS ANALYZER
Mass Analyzer
Quadrupole Mass Filter
Quadrupole
The system is compatible with the GCMS-QP2020 NX, GCMS-QP2020, and GCMS-QP2010 Ultra models, suggesting the potential use of a quadrupole mass analyzer.
CHROMATOGRAPHY AND SAMPLE HANDLING
Chromatography
Gas Chromatography (GC) using pyrolysis (Py-GC/MS).
Sample Handling
Sample preparation is solvent-free—simply cut, place in a cup, and weigh. A sampling toolkit is included, with phthalate ester standards prepared using a micro puncher.
Injection System
The system uses the AS-1020E auto-shot sampler.
DATA ACQUISITION AND ANALYSIS
Data Acquisition
Automatically flags key components based on semi-quantitative results, odor thresholds, and initial odor detection data.
Data Analysis
The software features a correction factor database for compound area ratios, enabling quantification with a subset of standards. It auto-generates calibration curves for non-standard compounds, calculates concentrations, and presents results in a color-coded table.
AUTOMATION AND SOFTWARE
Automation
- Automatically starts continuous analyses after setup.
- Requires entry of sample count, names, and weights.
- Accuracy control ensures reliable blank concentrations, instrument sensitivity, and data quality.
Software
- Uses GCMSsolution™ (Ver. 4.53+) and LabSolutions Insight™ (Ver. 3.8 SP1+).
- Includes EGA-PY3030 (Ver. 1.54+).
- Py-Screener software offers a user-friendly interface for guided procedures.
OPERATIONAL FEATURES
Ease of Use
Designed for novice users, the system includes specialized software and a sampling toolkit for easy operation. The maintenance navigator provides step-by-step guidance, photos, troubleshooting solutions, and a consumables list for effortless pyrolyzer and GC-MS upkeep.
Maintenance and Durability
The system features durable, long-lasting columns optimized for Py-Screener Ver. 2, reducing maintenance and costs. The SH-1MS column with an integrated guard column prevents leaks and protects compounds.
Operating Conditions
Temperature: 10-40°C
Humidity: 20-80% RH
Humidity: 20-80% RH
Power and Cooling
100-240V AC, 50/60 Hz
Requires external cooling unit
Requires external cooling unit
Dimensions and Footprint
300 mm (W) x 500 mm (D) x 150 mm (H)
GENERAL INFORMATION
Brand and Model
Shimadzu Py-Screener Ver.
Documentation and Support
The system includes method files that specify the instrument parameters for accurate identification of registered substances.
Sample preparation videos are also available.
Sample preparation videos are also available.
Compatibility and Connectivity
Py-Screener Ver. 2 supports the EGA/PY-3030D pyrolyzer, AS-1020E sampler, GCMS-QP2020 series, and GCMSsolution™ & LabSolutions Insight™ software. It integrates with EDX for system management and recommends the AP125WD-AD balance and STABLO-AP ionizer for optimal performance.
Configuration and Options
Users can select from a simultaneous inspection method (normal or high-speed) for phthalate esters and brominated flame retardants or a special high-speed inspection method for phthalate esters only.
Licensing and Certification
CE certified
ISO 9001
ISO 9001
Cost and Operational Expenses
Depends on the configuration, typically varies based on contract terms