Waters SELECT SERIES MRT
Mass spectrometry with Multi-Reflecting TOF for ultra-fast and accurate analysis.
Features
- Ultra-fast acquisition
- High resolution
- TOF technology
- Precise data
Applications
- High-throughput analysis
- Proteomics
- Metabolomics
- Pharmaceutical research
Product Specifications
PERFORMANCE
Mass Accuracy
±200 ppb RMS error with internal calibrant
Resolution
MRT mode: >200,000 FWHM @ m/z 785 and independent of scan speed
REM mode: >300,000 FWHM @ m/z 785
Diamond mode: >10,000 FWHM @ m/z 785 and independent of scan speed
REM mode: >300,000 FWHM @ m/z 785
Diamond mode: >10,000 FWHM @ m/z 785 and independent of scan speed
Sensitivity
Full scan sensitivity in MS/MS analysis (100 fmol/µL infused at 5 µL/min, >200,000 resolution)
Speed
>30 Hz acquisition rate
Dynamic Range
Up to 5 orders of magnitude
MASS RANGE AND ANALYTE DETECTION
Mass Range
MRT mode: m/z 50-9600
REM mode: m/z 100-2000
Diamond mode: m/z 50-20,000
Quadrupole: up to 8000 m/z
REM mode: m/z 100-2000
Diamond mode: m/z 50-20,000
Quadrupole: up to 8000 m/z
Detection Limit
Indicated by MS/MS analysis, but specific value not stated
Detector
Not specified
IONIZATION, SOURCE AND INTERFACE
Ionization Method
LockSpray Exact Mass Ionisation Source is supported.
Additional source options include DESI XS, NanoLockSpray, ASAP, and APCI
Additional source options include DESI XS, NanoLockSpray, ASAP, and APCI
Ion Source
LockSpray Exact Mass Ionisation Source
DESI XS
NanoLockSpray
ASAP
APCI
DESI XS
NanoLockSpray
ASAP
APCI
Interface
Not specified
Gas Flow and Requirements
Not specified
MASS ANALYZER
Mass Analyzer
Likely a Mass Reflectron Time-of-Flight analyser
Quadrupole
m/z range up to 8000 m/z
Isolation: 1 Da up to m/z 1000 and 2 Da up to m/z 2000
Isolation: 1 Da up to m/z 1000 and 2 Da up to m/z 2000
CHROMATOGRAPHY AND SAMPLE HANDLING
Chromatography
Not specified
Sample Handling
LockSpray Exact Mass Ionisation Source flow rate: 10 µL/min to 2 mL/min
Injection System
Infusion based on sensitivity description
DATA ACQUISITION AND ANALYSIS
Data Acquisition
>30 Hz acquisition rate
MS, MS/MS, MSⁿ, DDA
MS, MS/MS, MSⁿ, DDA
Data Analysis
MassLynx v4.2 with intuitive modern chrome instrument control software interface.
AUTOMATION AND SOFTWARE
Automation
Suggests potential for automated workflows
Software
MassLynx v4.2 with modern chrome instrument control interface
OPERATIONAL FEATURES
Ease of Use
Simple, intuitive experimental setup, acquisition, and data processing
Maintenance and Durability
Not specified
Operating Conditions
Mass calibration independent of calibrant mass and ionization mode.
Power and Cooling
Not specified
Dimensions and Footprint
Width: 855 mm (33.7 inches)
Length/Depth: 1904 mm (75 inches)
Height: 1700 mm (66.9 inches)
Length/Depth: 1904 mm (75 inches)
Height: 1700 mm (66.9 inches)
GENERAL INFORMATION
Brand and Model
Waters SELECT SERIES MRT
Documentation and Support
Document serves as part of the documentation
Calibration details provided
Calibration details provided
Compatibility and Connectivity
Instrument control software integrates the instrument operation.
Configuration and Options
Additional sources (DESI XS, NanoLockSpray, ASAP, APCI)
Modes: MRT, REM, Diamond
Modes: MRT, REM, Diamond
Licensing and Certification
Not specified
Cost and Operational Expenses
Not specified